voltarenyah / @voltarenyah/dsh-plcsim-advanced
A DeepSeek Harness distribution built for industrial automation
About this plugin
Written by the registry from verified metadata, not from the README.
@voltarenyah/dsh-plcsim-advanced is a DSH plugin published from the packages/dsh-plcsim-advanced package in the voltarenyah/dsh-automation-suite repository.
Capabilities and topics
@voltarenyah/dsh-plcsim-advanced
DSH plugin for S7-PLCSIM Advanced: manage local simulated PLC instances and exchange tags through the PLCSIM Advanced runtime API. It is the runtime half of the suite's simulation capability.
Status: runtime MVP, E2E verified. Instance lifecycle, TCP/IP or Softbus, RUN/STOP/reset and tag I/O work. The proven workflow with the TIA plugin is TIA
online_targets→ create a TCP/IP instance at the project IP → power on → TIAadopt_open_project/online_disconnect(force)/download→ read tags. Openness download needs two one-time prerequisites on the TIA side: the project PLC must have a subnet and unique IP, and the first connection must accept the self-signed certificate in the TIA UI. The complete handoff workflow is packages/dsh-tia-openness-v17-min/docs/HANDOFF-PLCSIM-DOWNLOAD.md.The certificate belongs to one virtual device, not to the project. A brand new instance is a new device with its own self-signed certificate, so its first CONNECT/download needs one manual Connect click in the TIA Portal UI; a
resume/restoreof an existing snapshot keeps the original identity and needs none. The tools therefore scan the workspace first: everycreaterefuses withsnapshots_availablewhile snapshots exist, and the agent asks the user whether to resume one or make a new device before retrying withconfirm_new=true. See Starting a simulation.F-CPU (fail-safe) projects are different — the virtual CPU must match the project CPU, and V17 Openness cannot download to an F-activated PLC at all. Read F-CPU (fail-safe) projects before creating an instance for a safety PLC.
What it does
| Tool | Actions | Notes |
|---|---|---|
simulation_status | read-only | API/Runtime version, licence, instances with name/comm/IP/state, this workspace's snapshot root and the snapshots found there |
simulation_instance | list / snapshots / create / power_on / power_off / remove / snapshot / snapshot_remove / restore / resume | create takes name, cpu_type or cpu_model, communication, ip; snapshots lists saved snapshots + live instances without starting anything; power_on applies the IP suite; snapshot saves a ZIP + fast storage and records the source project/checksum; snapshot_remove deletes one saved snapshot; resume reuses it; power_off/remove/snapshot_remove need confirm=true; create needs confirm_new=true once snapshots exist |
simulation_run | state / run / stop / reset | write actions need confirm=true |
simulation_tags | list / read / write | list capped (default 200); write needs confirm=true |
Coordinates the TIA side needs are returned directly: name, communication,
ip, subnetMask, gateway, state, cpuType, license. Rendered results
always carry that short fact line (Key facts: name=… state=… cpuType=…) even
with verboseResults off: in the 0.2.4 acceptance run a successful create
rendered only "succeeded", the model distrusted the empty answer and spent 20
minutes probing a healthy runtime.
Starting a simulation: scan, then choose
When the user asks to start a simulation, scan before creating anything:
simulation_status({}) // root + snapshots + live instances
simulation_instance({ "action": "snapshots" }) // the same scan, instance-shaped
create refuses with snapshots_available (naming the snapshots) unless
confirm_new=true, so the tool itself enforces the question. Present the choice,
then act:
- Resume (fast path) —
simulation_instance(action="resume", name="PLC_1", snapshot="plc1-first-run", run=true). The program is already in the snapshot: no TIA download, and no certificate click, because the snapshot keeps the original device identity (same MAC, same self-signed certificate). - New instance (slow path) —
createwithconfirm_new=true: a new virtual device, so its first TIA CONNECT/download needs the user to accept the new certificate once, and the program must be downloaded again.
The controller speaks one JSON object per line over stdio and holds the PLCSIM
Runtime Manager API client. Instances are kept running when the plugin unloads
(keepInstancesOnUnload, default true); remove is the explicit cleanup.
Proven workflow with the TIA plugin
- TIA
online_targets— read the target PLC's configured IP/subnet and the available PC interfaces (TCP/IP usesSiemens PLCSIM Virtual Ethernet Adapter). simulation_instance(action=create, name="<PROFINET device name>", cpu_type="1511", communication="tcpip", ip="<project IP>")— creates the instance and opens the PLCSIM Advanced Control Panel (showControlPanel, default true). The CPU family must match the project CPU; for an F-CPU project use the matching F type (cpu_type="1515F") orcpu_modelwith the order number/type name, never a standard family.simulation_instance(action=power_on, name=..., ip="<project IP>")— powers on and applies the IP suite. The instance should beSTOPand list an IP matching the project.- TIA
adopt_open_project— attach to the already-open TIA UI project. If the certificate has not been accepted yet, the user accepts it once in the TIA UI on the first connection. - TIA
online_disconnect(force=true)— drop any online state left by the UI. - TIA
download(dry_run=true)→download(confirm=true, options="software")— verify the target, then download. simulation_run(action=run, confirm=true)andsimulation_tags— confirm the program is running and exercise inputs/outputs.
The two plugins never call each other; the agent passes the coordinates between them.
F-CPU (fail-safe) projects — read before creating an instance
PLCSIM Advanced V7 does support fail-safe CPUs (manual §2.3), but the virtual CPU must match the project CPU. The V7 function manual §7.4 is explicit:
Loading project data of an F-CPU to a standard CPU is not possible.
That is exactly the TIA error The virtual PLC model does not match the project PLC model (虚拟 PLC 型号与项目 PLC 型号不符). The manual's two remedies:
- create the instance as the matching F-CPU:
cpu_type: "1515F"(the enum carries1511F…1518F), or bettercpu_model: "CPU 1515F-2 PN"/cpu_model: "6ES7 515-2FM01-0AB0"— the controller maps the project order number/type name to the PLCSIM CPU type (A= standard,F= fail-safe); or - create it as an unspecified CPU (
cpu_type: "unspecified"): the first download from TIA initializes the real CPU type.
Two more boundaries:
- TIA V17 Openness cannot download to an F-activated PLC at all
(
download_unavailable, coverage-matrix limitation R16). The download must be done in the TIA Portal UI (first connection: accept the self-signed certificate there). simulation_instancenever applies the IP suite oncreate; onlypower_ondoes (SetIPSuite). Powering on from the Control Panel leaves the instance on PLCSIM's own IP, which also makes a download fail.
So when the user asks to simulate a safety PLC / F-CPU, say up front that the
suite cannot finish the flow automatically: create + power on the instance with
the matching F type (or unspecified), then the user downloads from the TIA Portal
UI. Do not create a standard family instance for an F project, and do not
report "the runtime is missing" — the runtime is fine; the download path is the
limit.
Detect the CPU from the project hardware export (hardware_inventory: order
number/type name such as 6ES7 515-2FM01-0AB0, CPU 1515F-2 PN) and pass it as
cpu_model. cpu_model accepts the family (1515, 1515F, CPU 1515F-2 PN) or
the order number (6ES7 515-2FM01-0AB0; A = standard, F = fail-safe). Compact
(C), technology (T/TF), R/H and ET 200SP families are refused with
invalid_cpu_type instead of silently creating the wrong instance. safety_status
returning NOT AVAILABLE is not evidence of a non-F CPU (see
HARDWARE-CONFIG-SCOPE.md).
Persistence: snapshot and restore
After the first successful download/run, save the whole simulated PLC (program, hardware configuration and retentive data) as a PLCSIM archive ZIP:
simulation_instance({ "action": "snapshot", "name": "PLC_1", "snapshot": "cylinder-baseline" })
This writes under the workspace snapshot root, <workspace>/.dsh/simulation/,
where <workspace> is the session working directory of the call:
<workspace>/.dsh/simulation/cylinder-baseline/
instance.zip # ArchiveStorage(): program + hardware + retentive data
storage/ # fast copy of the Virtual SIMATIC Memory Card
manifest.json # name, cpuType, communication, ip, source { project/checksum }, runtime
The root is derived per call from the session workspace (exec.agent.session.header.cwd),
never from the host process working directory: a snapshot saved under the host cwd
was invisible to the next session in the same workspace, was not covered by that
workspace's backups, and vanished from view after a host restart. An explicit
snapshotRoot configuration still pins one shared root for every workspace.
snapshot uses the official IInstance.ArchiveStorage(zip) plus a directory
copy for the fast path; the instance must have been powered on at least once. If
it is running, the plugin briefly powers it off, archives, then restores its
previous state (RUN is resumed).
Next time, use the fast resume path — no TIA, no download:
simulation_instance({
"action": "resume",
"name": "PLC_1",
"snapshot": "cylinder-baseline", // optional; defaults to name
"run": true
})
resume is the recommended non-first-run entry:
- if the instance is still registered/running, attach with
CreateInterface; - otherwise copy the snapshot's
storage/directory (fast), register, power on, apply the manifest CPU/communication/IP, optionally RUN; - if an older snapshot has no
storage/, fall back toRetrieveStorage(zip).
restore remains available when you want an explicit new instance from a
snapshot; fast=false forces the ZIP path.
Snapshot provenance and cleanup
Every snapshot records which managed project it came from and the compiled PLC checksum, read from the workspace files the engineering-context plugin already writes:
source/_dsh-engineering-context.json -> project name/path + device/software
source/<device>/_evidence.json -> plcChecksum + stateId
The controller stores that as source in manifest.json (schemaVersion 2) and
also records runtime.plcsimVersion / runtime.apiVersion. snapshots,
restore and resume compare the recorded checksum with the current ledger and
report stale=true when the program has changed since the snapshot — a warning,
not a refusal, because resuming the old program may be exactly the point.
simulation_instance({ "action": "snapshots" }) // each row: checksum, stale
simulation_instance({ "action": "snapshot_remove", "snapshot": "old-baseline", "confirm": true })
snapshot_remove deletes one snapshot directory and never touches a registered
instance; remove remains the instance action.
Snapshots are local artifacts: keep the snapshot root out of git (the default
.dsh/simulation/is ignored by the repository). A snapshot is tied to the PLCSIM Advanced version that created it.
Safety
- Default communication is Softbus; the Openness workflow explicitly opts into TCP/IP to match the project IP. Softbus is only exposed by TIA V20; V17 Openness shows TCP/IP only. TCP/IP uses the PLCSIM virtual adapter, not a physical adapter mapping.
- Power-off/remove and every write require
confirm=true. - The plugin never loads a program and never writes a TIA project.
- F-CPU projects: a standard-CPU instance cannot take F project data (manual
§7.4); use the matching F
cpu_type/cpu_model(orunspecified) and remember that V17 Openness cannot download an F-activated PLC — the user must download from the TIA Portal UI.
Configuration
Every field has a default; a profile may insert the bundle without a config block.
| field | default | meaning |
|---|---|---|
controllerPath | '' | bundled controller/bin/PlcsimAdvanced.Controller.exe |
apiDir | C:\Program Files (x86)\Common Files\Siemens\PLCSIMADV\API\4.0 | API assembly folder; never copied into the package |
storageRoot | %TEMP%\dsh-plcsim | root of per-instance storage directories |
snapshotRoot | '' (= <workspace>/.dsh/simulation) | root of snapshot ZIPs and manifests; empty derives it per call from the session workspace, a value pins one shared root |
networkMode | softbus | default when create does not pass communication; the download workflow passes tcpip |
showControlPanel | true | start the PLCSIM Advanced Control Panel on the first create |
controlPanelPath | PLCSIM Advanced bin\...UserInterface.exe | Control Panel executable |
keepInstancesOnUnload | true | leave instances running when the plugin unloads; remove cleans up |
requestTimeoutMs | 120000 | per-operation deadline |
startupTimeoutMs | 30000 | ready-handshake deadline |
shutdownGraceMs | 5000 | graceful controller shutdown |
maxQueue | 8 | queued requests before new ones are refused |
logControllerOutput | false | forward controller stderr to the plugin logger |
verboseResults | false | include the full controller payload in rendered text |
The API baseline is PLCSIM Advanced 4.0 (4.0.0.4303): it covers 4.0–7.0
because the Runtime Manager is backward compatible (V7 verified in the
assessment). The controller resolves Siemens.Simatic.Simulation.Runtime.Api.x64
from apiDir at run time and never ships the Siemens DLL.
Build and test
# once on a bare checkout: link the shared DSH runtime from <DSH_HOME>\plugin-runtime
npm run link:runtime
npm run build
npm run build:controller # needs a PLCSIM Advanced install with API\4.0 and the .NET SDK
npm test
build:controller also runs --self-test, which checks the JSON framing,
operation whitelist, CPU mapping, snapshot listing and API probe without a
running instance. The TypeScript tests need the real DSH runtime links
(link:runtime), like the sibling plugins.
Layout
src/
index.ts host row: controller + plcsimRuntime seam, no tools
tools.ts four model tools
tools-entry.ts /tools row (declared by the leader preset)
workspace.ts session workspace -> <workspace>/.dsh/simulation
controller.ts subprocess lifecycle, NDJSON, deadlines
protocol.ts wire frames and the operation whitelist
config.ts Config schema and defaults
runtime-service.ts the internal seam between the two rows
controller/
Program.cs stdio controller, API 4.0 adapter, TCP/IP + IP suite, UI
CpuTypes.cs project CPU designation/order number -> ECPUType
build.ps1 builds controller/bin and runs --self-test
bin/ prebuilt exe (no Siemens API DLL)
test/ node:test protocol + tool forwarding
Badge
Listed here? Link back with this badge — paste the snippet into your repository README.
[](https://dsh-plugin.com/plugins/voltarenyah/dsh-automation-suite/packages/dsh-plcsim-advanced)