voltarenyah / @voltarenyah/dsh-tia-openness-v17-min
A DeepSeek Harness distribution built for industrial automation
About this plugin
Written by the registry from verified metadata, not from the README.
@voltarenyah/dsh-tia-openness-v17-min is a DSH plugin published from the packages/dsh-tia-openness-v17-min package in the voltarenyah/dsh-automation-suite repository.
Capabilities and topics
TIAOpennessV17Min
DeepSeek Harness 插件:通过 TIA Portal V17 Openness 对 PLC 程序块做最小化读写 (导出 / 导入 Simatic ML、外部源生成块、编译验证)。
A DeepSeek Harness plugin that exposes TIA Portal V17 Openness as 39 model-facing tools backed by a whitelisted C# controller subprocess, including the project library (types/versions and master copies). Every write runs in an exclusive-access transaction and is read back for verification; the operations whose preview carries information are dry-run by default.
插件由两个 Loader 行组成:宿主行(
.,src/index.ts)持有控制器子进程、engineeringAccess与projectTextAccess服务与知识库;工具行(./tools,src/tools-entry.ts)才是 39 个模型可见的工具, 由 agent preset 决定要不要声明 —— 主 agent(leader)声明它、子 agent(expert)不声明, 于是子 agent 看不到任何 TIA 工具。见 §4.0。
1. 它解决什么问题
模型需要读取/修改 TIA Portal 项目里的 PLC 程序块,但:
- Openness 只能被 .NET Framework 64 位进程调用,不能直接从 Node 进程调用;
- Openness 对象非线程安全,并且一次只能有一个 Openness 客户端;
- 写操作如果失败,必须保证项目不被写坏;
- 不能把"任意代码执行"能力暴露给模型。
本插件用两层解决:
┌─ DSH 宿主进程 (Node) ──────────────────────────┐
│ dsh-tia-openness-v17-min (本插件, TypeScript) │
│ 宿主行 ('.'): │
│ • ctx.effect() 拥有 C# 控制器子进程 │
│ • 注册 engineeringAccess 服务(公开缝) │
│ • 注册 tiaOpennessRuntime(本包工具行的内部缝)│
│ • 注册知识库 skill provider │
│ 工具行 ('./tools',按 preset 声明): │
│ • 注册 39 个模型可见工具 │
│ • 请求串行化 / 超时 / 硬超时终止与重启 │
│ • 结构化错误 → 结构化工具结果 │
└───────────────┬────────────────────────────────┘
│ NDJSON over stdin/stdout(一行一帧)
┌───────────────▼────────────────────────────────┐
│ TiaOpennessV17Min.Controller.exe (C#, x64, │
│ .NET Framework 4.8) │
│ • 先注册程序集解析器,再加载 │
│ Siemens.Engineering.dll(V17) │
│ • 只执行 40 个白名单操作 │
│ • 写入 = ExclusiveAccess + Transaction │
│ • 写后读回验证 │
│ • 返回结构化 JSON │
└────────────────────────────────────────────────┘
一个宿主进程只有一个控制器子进程,因此整个 profile 共享一个 TIA Portal 会话; 来自不同会话的请求在控制器内排队串行执行(Openness 本身也不允许并发)。
0. 验证状态(请先读这一段)
| 项目 | 状态 |
|---|---|
| TypeScript 构建 / typecheck | ✅ 0 错误 |
C# 控制器编译(对着本机真实 V17 Siemens.Engineering.dll) | ✅ 0 Warning / 0 Error |
自动化测试 npm test | ✅ 119 项:118 通过 / 0 失败 / 1 跳过(跳过项为"控制器未构建"的降级路径;含 9 项知识库、3 项对真实 skill 注册表的集成测试、6 项两行拆分契约与 13 项斜线指令测试——其中 2 项在真实 cordis 服务图上把两行当兄弟插件挂载) |
| C# 控制器自检(无 TIA) | ✅ 20/20(含"启动时不加载 Openness 程序集"与"Siemens 解析器包可用") |
| Openness 环境探测(DLL 版本 / 位数 / 用户组) | ✅ 17.0.0.0 / x64 / 已在 Siemens TIA Openness 组 |
| 安装进真实 DSH 宿主的加载 / 卸载验证 | ✅ 已验证(真实宿主):独立 DSH_HOME + 测试 profile 启动真实宿主 → 控制器子进程出现(apply 执行、ctx.effect 持有);宿主结束 → 子进程自行退出,无残留。~/.dsh 未被修改 |
| 真实 V17 项目上的导出→改→导入→编译 | ✅ 已验证(真实项目):237 块项目导出 234 个(3 个被 TIA 拒绝,逐块报告)、改 HeaderVersion 导入 override 进原组、写后验证 passed/changed=True、重新导出内容为新值、编译 errors=0。详见 §0.1 |
第二个真实项目(PEI_SinoARP_Master_V4.1.3,1152 块,正式项目,设备在用户组里) | ✅ 导出 1151/1152(1 个 Safety F 块被拒绝并逐块报告),1152 文件 / 70.6 MB,22 个用户组目录层级与非 ASCII 组名(Fonctions méthode、55_Cavité_STD)均正确;.ap17 修改时间未变、无锁文件、无残留进程。该轮又修掉一个缺陷(设备分组 → 见 REAL-RUN.md §D.6、decisions.md D16) |
| v0.2 新增的 20 个操作(工程数据 / PLC 数据 / F 相关) | ⏳ 已实现、编译通过、单测通过;尚未在真实 TIA Portal 项目上验证。逐条测试项与执行方法见 docs/VERIFICATION-PLAN.md;接口契约见 docs/EXTENDED-SURFACE.md |
项目库 project_library(Types / Master copies) | ✅ 已在真实 SWT1/SWT2 副本验证:browse、类型版本导出(含库包装层识别)、整库 export(SWT1 229 文件 / SWT2 406 文件,失败项逐条记录)、编辑后作为主副本发布、文件夹/主副本清理;主副本导出对不一致内容与 HMI 标签表分别返回结构化限制。详见 docs/PROJECT-LIBRARY.md §8 |
关于验证范围
上面两行已在真实环境跑通,且没有修改你的默认 profile:控制器直测、往返测试在项目副本上做 (
C:\tia-openness-test\),宿主验证用独立DSH_HOME。~/.dsh/profiles仍然是desktop, node_modules, web。仍然待人工验证的只剩两项(都需要人在界面/真实环境里操作,见
docs/verification.md§B):
- HMR disposer 路径:在运行中的实例里"禁用/启用插件",看
ctx.effect的 disposer 停掉并重启子进程 (脚本只能验证"宿主结束 → 子进程退出"这条 EOF 路径);- Openness 应用白名单:本机 V17 首次用新构建的控制器 exe 时会弹
Openness access对话框(exe 哈希变了)。选 Yes to all 才会把条目写进HKLM\SOFTWARE\Siemens\Automation\Openness\17.0\Whitelist\TiaOpennessV17Min.Controller.exe, 而写 HKLM 需要管理员权限;非管理员会话里选 Yes 只对当次会话有效,重新构建/换路径会再问。 受管环境或 V18+ 可能还要求额外的白名单条目(官方解析器自带WhitelistApp(),本插件尚未接线)。
0.1 真实环境实测结果(本轮)
| 步骤 | 结果 |
|---|---|
打开真实项目(副本,KPH_CellController_0822.ap17,213 MB) | ✅ 1 个 PLC 软件 S7-1500/ET200MP station_1 / PLC_KPH_CellController_SIM,237 个块;首次冷启动 70.1 s,热启动 9.8–24.2 s |
| 导出全部块 | ✅ 234 个成功(235 文件 / 33.9 MB,用户组目录层级保留),3 个被 Openness 拒绝并逐块记录:ProDiagOB(语言 ProDiag_OB 不支持)、Default_SupervisionFB(语言 ProDiag)、FOB_RTG1(Safety F-OB "export is not permitted");每个写出文件都读回校验(verified=True)+ manifest 记 SHA-256 |
| 导出预演 / 编译预演 | ✅ 正确列出 237 个文件 / 237 个待编译块;239 个 progress 帧证明长操作可观测 |
| 修改 → 导入(override)→ 写后验证 | ✅ 改 HeaderVersion 0.1→0.2,导入到原组 999_Kautex:committed=True、verification.passed=True、confirmedCount=1、group='999_Kautex/'、replacedExisting=True、changed=True、ModifiedDate 已更新 |
| 重新导出对比内容 | ✅ 重新导出的 <HeaderVersion> = 0.2(证明改动真的写进了项目,不是"没报错") |
| 编译 | ✅ state=Warning, errorCount=0,FB_Array_Handling (FB34) 等块 "successfully compiled" |
| 真空退出 | ✅ 控制器退出后无残留 TiaPortal.exe、无残留控制器进程 |
| 真实 DSH 宿主加载/退出 | ✅ 见上表 |
这一轮真实项目测试抓出并修复了 3 个真缺陷(单元测试无法覆盖的): ① 真实导出的 XML 是
Document > Engineering > DocumentInfo > SW.Blocks.*,我的解析器把<Engineering>当成了块元素 → 导入预演拿不到块名、写后验证静默失效;② 一个不可导出的块会中止整批导出; ③ 导入固定落在根组 → 位于用户组的块即使override也无法覆盖("name or number already exists")。 细节与证据见docs/decisions.mdD14/D15 与docs/verification.md§D。
2. 环境要求
| 项目 | 要求 |
|---|---|
| 操作系统 | Windows(仅限;插件在其它平台能加载,但所有工具调用会返回 controller_not_found) |
| TIA Portal | V17(严格绑定,不兼容 V16/V18) |
| Openness DLL | C:\Program Files\Siemens\Automation\Portal V17\PublicAPI\V17\Siemens.Engineering.dll(可用 --openness-dir / TIA_OPENNESS_V17_DIR 覆盖) |
| .NET Framework | 4.6.1+(本控制器以 4.8 为目标框架构建) |
| 进程位数 | x64(Openness 是 64 位 API) |
| Windows 用户组 | 当前用户必须属于本地组 Siemens TIA Openness |
| DSH | 任何能加载 bundle 的版本(宿主行 inject: [];工具行 inject: ['tools', 'tiaOpennessRuntime']) |
| 重新构建 C# 时才需要 | .NET SDK(\dotnet build\)+ .NET Framework 4.8 targeting pack + 能访问 NuGet 源(首次还原约 13 秒,见 §7.1) |
| 重新构建 TS 时才需要 | Node ≥ 22.19、npm install(只装 typescript 与 @types/node) |
检查用户组:
net localgroup "Siemens TIA Openness"
3. 安装
3.1 已构建产物
仓库已包含构建结果,安装前无需编译:
lib/—— TypeScript 编译输出(宿主行入口lib/index.js;工具行入口lib/tools-entry.js, 即exports["./tools"])controller/bin/TiaOpennessV17Min.Controller.exe(+.exe.config)—— C# 控制器
3.2 安装到 DSH profile
用内置的插件管理器(Web 侧边栏 Plugins 页,或 Creator 模式下的 plugin_manager 工具):
plugin_manager(action: "install_bundle", target: "C:\\Users\\Ansel\\dsh-automation-suite\\packages\\dsh-tia-openness-v17-min")
或直接在 profile 的 patch 层里加一行(~/.dsh/profiles/<profile>/cordis.patch.yml):
- insert:
- id: tia-openness-v17-min
name: '@voltarenyah/dsh-tia-openness-v17-min'
config:
requestTimeoutMs: 600000 # 大项目导入/编译可能需要更长时间
工具行要另行声明(宿主行只提供控制器与服务,不含任何模型可见工具):
- insert:
- id: tia-openness-v17-min-tools
name: '@voltarenyah/dsh-tia-openness-v17-min/tools'
两条行可以放在 composition 的任意位置:工具行的 inject 会让 loader 等到 tiaOpennessRuntime
出现再调用它的 apply。但只有该看到 TIA 的 agent preset 才应该声明工具行 ——
把它写进全局组合等于回到拆分之前(见 §4.0)。
本插件的 bundle patch(cordis.patch.yml)只插入宿主行那一条,不含任何环境相关配置,
因此同一份 bundle 可以装在任意 profile。profile 的 patchReload 不是 live 时需要重启 DSH 才会生效。
3.3 配置项(全部有默认值,可整块省略)
| 字段 | 默认 | 说明 |
|---|---|---|
controllerPath | '' | 控制器 exe 的绝对路径;空 = 使用包内 controller/bin/...。也支持环境变量 TIA_OPENNESS_V17_MIN_CONTROLLER |
opennessDir | '' | 传给控制器的 --openness-dir;空 = 控制器默认路径 |
requestTimeoutMs | 300000 | 单次操作的硬超时(毫秒)。超时会终止控制器(Openness 无法取消),下一次调用自动重启 |
startupTimeoutMs | 30000 | 启动握手超时 |
shutdownGraceMs | 5000 | 卸载时先关闭 stdin 优雅退出,超时后强杀 |
maxQueue | 8 | 排队上限,超出返回 controller_busy |
logControllerOutput | false | 把控制器的 stdout/stderr 转发到 DSH 日志 |
verboseResults | false | 工具结果里附带完整控制器 payload |
4.0 三个 Loader 行:宿主行、/tools 行与 /commands 行
DSH 按声明作用域决定工具对谁可见:一行里注册的工具属于该行的作用域。插件原来把全部工具
和控制器放在同一行,于是它们落在宿主(全局)平面上 —— 任何 agent(包括被派生的子 agent)
都继承。发行版要区分 leader(主 agent,保留 39 个工具)与 expert(子 agent,不应看到任何
TIA 工具),所以注册被拆成两行;人用的斜线指令是第三个面,再拆一行:
| 行 | 子路径导出 | name | inject | 内容 |
|---|---|---|---|---|
| 宿主行 | .(lib/index.js) | tia-openness-v17-min | [] | ControllerProcess + ctx.effect 的所有权、engineeringAccess 服务(只读公开缝)、projectTextAccess 服务(项目文本/语言/归档/保存的写缝)、tiaOpennessRuntime(本包另两行的内部缝)、bundled skill provider |
| 工具行 | ./tools(lib/tools-entry.js) | tia-openness-v17-min-tools | ['tools', 'tiaOpennessRuntime'] | 39 个模型可见工具(src/tools.ts) |
| 命令行 | ./commands(lib/commands-entry.js) | tia-openness-v17-min-commands | ['commands', 'tiaOpennessRuntime'] | 7 个 /tia-… 斜线指令(src/commands.ts,复用工具的操作与渲染) |
- 只有该看到 TIA 的 preset 才声明工具行:
leader声明它 → 保留 39 个工具;expert不声明 → 一个 TIA 工具都没有。宿主行对所有 agent 都加载,因为控制器与会话是 composition 级资源。 - 命令行独立于工具行:它不注册任何工具,也不要求
/tools行存在;一个只想给人用/tia-open的 preset 可以只声明命令行。反过来,声明工具行不会让命令出现。 - 宿主行没有工具,所以
inject是空数组;它唯一想等的skills是可选的, 仍旧走apply里的ctx.inject(['skills'], …),缺 skill 注册表的 profile 照常加载。 - 工具行与命令行不拥有任何配置:所有配置(
controllerPath、requestTimeoutMs、verboseResults…) 都写进宿主行,两行都从tiaOpennessRuntime读回已经归一化的值。 - 一个 composition 仍然只有一个控制器子进程 / 一个 TIA Portal 会话,无论多少 agent 声明这些行。
inject让顺序安全:工具行/命令行可以在 composition 里写在宿主行之前,loader 会等tiaOpennessRuntime出现再调用它们的apply。反过来,只声明它们而不声明宿主行, 它们就一直等不到那个服务、什么也不注册。
4. 工具
工具行注册的 39 个工具,统一返回同一个信封(ok / summary / data / changes / diagnostics / error)。
每个工具对应控制器的一个白名单操作,参数与返回结构见
docs/EXTENDED-SURFACE.md。
块与工程主线(v0.1 已有)
| 工具 | 作用 | 写入 | 默认 dry-run |
|---|---|---|---|
open_project | 打开(或附加到已运行的)TIA Portal V17 项目;默认带界面窗口,已占用的窗口不会被借用而是新起一个可见实例,headless 需显式 with_window=false | 仅当 allow_upgrade=true | 否(升级写入由 allow_upgrade 单独把关) |
export_blocks | 导出 PLC 块为 Simatic ML XML(每块一个文件,保留用户组目录) | 否(只写文件系统) | —(无 dry_run) |
import_blocks | 导入 Simatic ML XML 或 SCL/STL 外部源 | 是 | 是 |
compile_plc | 编译 PLC 软件并返回编译结果 | 是(编译状态) | —(无 dry_run) |
close_project | 关闭项目(可选保存、可选关掉 TIA Portal 实例) | 是(保存/关闭会话) | 是 |
controller_status | 报告控制器子进程与 Openness 环境状态 | 否 | —(不启动控制器) |
工程与工程数据(v0.2 新增)
| 工具 | 作用 | 写入 | 默认 dry-run |
|---|---|---|---|
create_project | 新建工程(可选 Author/Comment),并保持打开 | 是(新目录 + 新工程) | —(无 dry_run) |
save_project | 保存工程,或另存到 save_as_dir | 是 | —(无 dry_run) |
archive_project | action=archive 归档当前工程;action=retrieve 取回归档并打开 | 归档只写文件;取回打开工程 | —(无 dry_run) |
project_info | 只读汇总:工程属性、注释、语言、历史、已用产品、设备树、PLC 软件、TIA 设置 | 否 | —(无 dry_run) |
project_languages | 列出/设置支持语言、活动语言、编辑语言、参考语言 | 是(action=set) | —(无 dry_run) |
project_texts | 导出/导入整工程文本(xlsx,ExportProjectTexts/ImportProjectTexts) | 导出只写文件;导入改工程(无事务,不可回滚) | —(无 dry_run) |
project_library | 读/改项目库:action=browse 列类型/版本/主副本;read 导出单个 XML;export 整库导出到 <workspace>/library/ + _manifest.json;write/publish 把编辑后的 XML 或工程对象发布为主副本;organize 建夹/改名/删除/复制/设默认版本;use 实例化/更新工程实例/查实例与依赖 | 是(write/publish/organize/use) | 是(write/publish/organize 及 instantiate/update_project) |
update_project | 写"块编译时仿真支持"与工程注释(多语言文本) | 是 | —(无 dry_run) |
portal_settings | 列出/修改 TIA Portal 设置(SettingsFolders,如 General/SearchInProject) | 是(action=set) | —(无 dry_run) |
PLC 设备数据(v0.2 新增)
| 工具 | 作用 | 写入 | 默认 dry-run |
|---|---|---|---|
list_plc_objects | 只读枚举块/PLC 类型/标签表(含变量与常量)/外部源/监视表/力表/软件单元,可带属性与指纹 | 否 | —(无 dry_run) |
create_plc_objects | 建块组/类型组/标签表组/标签表/监视表/软件单元/单实例 DB | 是 | —(无 dry_run) |
delete_plc_objects | 删块/类型/标签表/监视表/软件单元/各类组/变量/用户常量 | 是 | 是 |
write_tags | 建/改/删 PLC 变量与用户常量(含注释、外部可见性) | 是 | 是 |
set_block_attributes | 通用 SetAttribute 写块/UDT 属性(如 OB 的 Priority) | 是 | 是 |
protect_blocks | 设置/解除块 know-how 保护(PlcBlockProtectionProvider) | 是 | 是 |
generate_source | 由块/UDT 生成 .scl/.awl/.db/.udt 源文件 | 只写文件 | —(无 dry_run) |
watch_and_force_tables | 监视表的建/删/导出/导入、力表的导出/导入 | 是 | —(无 dry_run) |
software_units | 软件单元的列出/创建/删除、关系增删 | 是 | —(无 dry_run) |
块编辑器(界面动作,v0.3 新增)
| 工具 | 作用 | 写入 | 默认 dry-run |
|---|---|---|---|
show_blocks_in_editor | 在 TIA Portal 的块编辑器里打开块 —— 一次请求批量打开(单次 ≤100 个),Group/Name 可消歧 | 否(不碰工程、不存盘;效果是界面动作) | —(无 dry_run) |
它等价于在项目树里逐个双击块,底层是 Siemens.Engineering.IShowable.ShowInEditor()
(V17 反射:PlcBlock 及 OB/FB/FC/DataBlock 等都实现它)。三条硬约束:
- 必须有带界面的 TIA Portal。工程用
open_project(with_window=false)打开的无界面实例报editor_unavailable,唯一的补救是close_project后用with_window=true重开(或adopt_open_project接管操作者已开好的窗口)—— 块属于那个无界面实例,没有编辑器可开; - 先解析后打开:名单里有一个名字不存在就是整单
block_not_found,裸名字在多个用户组里 重名则block_ambiguous,不会留半批编辑器在界面上; - 逐块独立:某个块被 TIA 拒绝(如 know-how 保护块弹密码框)只进
data.failed, 其余照开;一块都没开才editor_show_failed。
真机实测(2026-11-04,V17):带界面会话里的 PEI_HF_M4L_ZRW_Test_V5.1(782 块)上,
单块 3.1 s、三个块(OB + FB + InstanceDB)5.2 s 全部开出编辑器并逐块回报;
["NoSuchBlockXYZ"] 报 block_not_found 且一个编辑器都没开。逐块约 1.7 s。
F 相关(v0.2 新增)
| 工具 | 作用 | 写入 | 默认 dry-run |
|---|---|---|---|
safety_status | 只读:GlobalSettings 两个动作、SafetySettings、SafetyAdministration、运行时组 | 否 | —(无 dry_run) |
set_safety_settings | 写 SafetyModificationsPossible 与 UsernameForFChangeHistory | 是 | —(无 dry_run) |
safety_signatures | 只读:逐块 SafetySignatureProvider 的 F 签名(BlockOfflineSignature) | 否 | —(无 dry_run) |
硬件组态(v0.3 新增)
| 工具 | 作用 | 写入 | 默认 dry-run |
|---|---|---|---|
export_hardware_config | 导出工程级硬件组态为单个 AutomationML(CAx/AML)文件,默认落盘 <workspace>/hardware/globalHardware.aml(日志同级 globalHardware.log) | 否(只写文件系统;独占访问内执行,不 Save、不改工程) | —(无 dry_run) |
hardware_inventory | 读导出的 AML,返回元器件身份:设备/用户组、机架、每槽模块的型号、订货号、固件版本、通道数 | 否(只读文件,不需要打开工程) | —(无 dry_run) |
hardware_configuration | 读导出的 AML,返回组态值:I/O 地址与通道宽度、PLC 标签、网络(IP/掩码/PROFINET 名/IO 系统)、连线(端口↔端口、节点→子网、接口→IO 系统)与信号映射(通道↔标签)、F 地址 | 否(只读文件) | —(无 dry_run) |
hardware_parameters | 读对象模型的参数:模块/通道发布的属性名与值、GSD 身份(AML 里没有这一层) | 否(只读) | —(无 dry_run) |
export_hardware_config 只产出文件;解析由两个只读工具负责(hardware_inventory / hardware_configuration),它们读文件、不需要打开的工程。export_hardware_config 的返回值仍是:
allObjectsExported、日志计数器(logSummary{errors,warnings})与被跳过的对象(logProblems[])。
返回里另有 notInAml[]:AML 里没有的设备(HMI 首当其冲)的名字、类型、以及每个节点的
address / subnetMask / pnDeviceName / subnet——这些正是 AML 条目会带的字段,
HMI 因为在 CAx 里没有类模型,只能出现在这里。deviceCount - notInAmlCount 就是文件覆盖的设备数。
allObjectsExported 的语义是"所有对象都导出了",不是"产出文件了":实测 PEI_SinoARP_SWT2(2026-11-02)
返回 false 却写出了完整的 1.4 MB CAEX 2.15 文档,日志结尾 completed (errors: 1, warnings: 0),
唯一那条 error 是 device HMI_1 is being skipped … TypeIdentifier is invalid or missing ——
正是一个 CAx 无法表达的对象。所以 false + 合法文件 = 部分成功,工具照常返回成功并逐条列出被跳过的对象。
手册同一条目列出的导出禁区(除按键面板外的 HMI、多 CPU、扩展机架连接、端口到端口连接、模拟量通道输出模式、
压缩地址,以及手册所说的"驱动")意味着不要把 AML 当成完整清单——但它也不是可靠的预测:
2026-11-02 在一个 18 台设备的真实工程上实测,只跳过了 1 台 HMI,17 台全部导出,包括 GSDML 形式的驱动与
第三方设备。所以判断"丢了什么"以 logProblems 为准,而不是按类别假设。
4.1 典型流程:导出 → 修改 → 导入 → 编译
// 1) 打开项目(默认带界面窗口;无人值守才传 "with_window": false)
{ "project_path": "C:\\Projects\\Line1\\Line1.ap17" }
// 2) 导出全部块(或指定 block_names)
{ "output_dir": "C:\\Projects\\Line1\\export", "block_names": ["Main", "FB_Motor"] }
// 3) 先预演导入(默认 dry_run=true):校验文件、解析目标块名、报告冲突
{ "import_paths": ["C:\\Projects\\Line1\\export\\FB_Motor.xml"] }
// → data.ready / data.plan / data.conflicts,项目未被修改
// 4) 真正导入(覆盖已存在块需要 import_options: "override")
{ "import_paths": ["C:\\Projects\\Line1\\export\\FB_Motor.xml"],
"import_options": "override", "dry_run": false }
// → data.committed=true,data.verification.passed=true(读回块集合验证)
// 5) 编译验证
{ "compile_plc": {} } // 真编译:返回 state/errorCount/warningCount/messages
// 6) 保存并关闭
{ "save": true, "dry_run": false }
4.2 dry-run 与写入策略
dry_run 只留给"预览本身带信息量"的工具(决策 D22):预览要能把模型
自己算不出来的东西查出来 —— 把名字/路径解析成真实对象、把冲突与现有状态 diff 出来 —— 而且
真正的风险落在写入那一步。满足这两条的有:
- 默认
dry_run: true(必须先预演,再显式传dry_run: false):import_blocks(逐文件解析 + 目标块名解析 + 冲突与组不匹配)、delete_plc_objects(解析出真实删除集合与存在性)、write_tags、set_block_attributes、protect_blocks(逐对象 before/after 与当前保护状态)、close_project(会丢弃哪些未保存改动)、project_library的写子面(write/publish/organize以及use的instantiate/update_project:预演解析目标名、是否已存在、版本与内容类型)。 open_project的dry_run默认false且是零 TIA 接触:它连 TIA Portal 都不启动, 只校验路径;唯一可能的写入(升级重写项目)由独立的allow_upgrade(默认false)把关。- 其余工具没有
dry_run(或只在project_library的写子面有):export_blocks、compile_plc、create_project、save_project、archive_project、project_languages、project_texts、update_project、portal_settings、create_plc_objects、generate_source、watch_and_force_tables、software_units、set_safety_settings、show_blocks_in_editor。理由分两类:(a) 它们写的是一两个具名对象,真的调用会在写入前干净失败 (object_already_exists、group_not_found、language_not_found、setting_not_found、file_exists), 预演买不到额外安全;(b) 预览只是把入参复述一遍(wouldWrite: true),没有信息量 ——show_blocks_in_editor属于 (b):它不写工程,预览只能把块名单再念一遍。 - 读操作(
project_info、list_plc_objects、safety_status、safety_signatures)不声明dry_run: 它们不写任何东西。 - 例外需要记一笔:
project_texts的action=import不包在事务里(Openness 手册禁止在事务内做 ProjectText 导入),所以它无法回滚;去掉 dry-run 后这一处没有确认步骤,若将来要补,正确机制是 用户审批(DSH 的 approval 门),而不是一个零信息量的预演。 - 每个工具的
description都写明了上述策略,模型可以直接读到。
4.3 写后验证
- 导出:写入的每个 XML 都被读回解析,校验非空、根元素、
<Name>与预期块名一致, 并记录 SHA-256;同时在输出目录写_manifest.json便于审计。任一文件校验失败 → 整个调用返回verification_failed,并在data中给出已写入的文件清单。 - 导入:事务提交后重新读取项目块集合,逐个确认目标块存在,并对比
ModifiedDate/Number/ProgrammingLanguage;缺失块 →verification_failed(data.committed=true说明写入确实发生了,错误里同时给出验证报告)。 - 编译:编译结果作为数据返回(
state/errorCount/warningCount/messages), 编译报错不是工具错误,而是让模型据此修正。
4.4 知识库:随包出货的 Openness skill(skills/)
插件把上游 Siemens 的 Openness skill 集
(siemens/tia-portal-ai-extensions,MIT,
commit b5c7041)逐字打进包里,并注册成模型可见的一个 skill tia-openness:
- 它是什么:一张「症状 / 任务 → 该读哪个文件」的路由表(独占访问、事务、Simatic ML 往返、
块组层级、编译、licensing/防火墙、线程、崩溃定位、性能……)。31 个上游文件(每个 4–23 KB)
作为资源放在
skills/<name>/SKILL.md,模型按需用read分段读取 —— 所以知识库不占常驻上下文,只在真正用到时付费。 - 为什么只注册一个:会话目录是每个会话都要付的持久消息,描述上限 500 字符;31 条目录项会让 每个(哪怕与 TIA 无关的)会话都替它买单。路由 skill 只占一行,同时把绝对 base directory 交给模型。
- 怎么注册:
src/skills.ts通过ctx.inject(['skills'], …)注册 bundled provider;skills没有被放进宿主行的模块级inject,所以未挂 skill 注册表的 profile 里 宿主行(以及工具行)照常加载。知识库属于宿主行:它是 composition 级的知识, 不是"某个 agent 的工具面",所以不随工具行一起按 preset 开关。 两条都有单测守着:test/06-skills.test.mjs用替身注册表,test/07-skills-registry.test.mjs用真实的@deepseek-ai/dsh-skill注册表(含"卸载后目录项消失")。 - 模型一定会看到它:每个工具的 description 末尾都带一句
Troubleshooting: load the bundled `tia-openness` skill …,会话目录里也有同名条目。 - 口径:上游是 V21 时代的语义(modular assemblies、
.s7dcl/.s7res、LTS 链重启), 本插件是 V17 子集 —— 上游回答"Openness 能不能做",本插件的能力边界仍以 §10 与docs/为准。 - 维护:
npm run skills:build(按 pinned commit 重新取上游)/npm run skills:check(离线校验 sha256、目录清单、上游依赖图、路由 skill 的体积与引用;已并入npm run check)。 为什么知识库不放docs/,以及细节与合规说明,见docs/KNOWLEDGE-BASE.md、skills/README.md、AGENTS.md§2 与THIRD_PARTY_NOTICES.md。
4.5 给工程上下文插件的服务:engineeringAccess
宿主行不注册任何模型可见工具,它注册三个 cordis 服务。公开的读缝是 engineeringAccess
(src/access.ts),供工程上下文插件调用 —— 它要指纹做工程级
变更检测,而按架构规定它自己不允许与 TIA Portal 对话(发行版
docs/decisions.md D12 的"缝 A")。项目文本/语言/归档/保存的
写缝是 projectTextAccess(src/project-text-access.ts),供翻译工作流使用;
tiaOpennessRuntime(src/runtime-service.ts)只给本包的工具行读,
不是公开接口。其它插件读工程走 engineeringAccess,写项目文本走 projectTextAccess。
| 方法 | 触发的操作 | 关键点 |
|---|---|---|
status() | —(只读控制器快照) | 报告"值不值得试":可执行文件在不在、Openness 探没探过;从不启动控制器 |
openProject(path, opts) | OpenProject | allowUpgrade 默认 false(打开唯一不可逆的写) |
closeProject(opts) | CloseProject | dryRun 是必填参数 —— 调用方是代码,不替它默认 |
listObjects(query) | ListPlcObjects | 把每族的 {count,items,truncated} 摊平成一行一对象;默认 max_items=1000 |
exportObjects(query) | ExportBlocks | 与 export_blocks 同参;只写文件,不动工程 |
saveProjectAs(dir) | SaveProject + save_as_dir | 另存到指定目录;回读 TIA 实际产出的路径(项目名改不了,只有目录是新的) |
retrieveProject(archive, dir, opts) | ArchiveProject + action=retrieve | 把 .zap17(或更早版本的归档)解包到指定目录并打开;回读 projectName / projectPath(取回保留归档里的工程名,与另存不同);upgrade 默认 false(更早归档要先得到调用方同意) |
readTiaSession() | ProjectInfo | 控制器在不在 + TIA 开着哪个项目 + 设备清单;从不启动控制器 |
rebuildSource(root, opts) | ProjectInfo + 每 device 两次 ExportBlocks | <root>/<device>/{blocks,types,tag_tables}/… 的布局由它定死;被 TIA 拒绝的对象逐条回报 |
readPlcChecksum() | PlcChecksum | 读 PlcChecksumProvider.Software;空值以 checksum_unavailable 回报(未编译/改动后未再编译) |
syncScan(query) | SyncScan | 用上一版 evidence 账本逐对象比对指纹/标签表哈希,并记录 F 块的 SafetySignatureProvider 签名(只对 F_* 语言或 OB 预筛后问 provider;F-OB 也能跟踪),只把差异导出到 STAGE,同一调用写下 _evidence.json 与 _manifest.json;checksum 一致时直接返回 unchanged(并回报 scanSkipped: true)。只改安全程序(F 块)不会移动 checksum,所以这条快速路径看不见它——forceScan: true 绕过快速路径强制枚举(工程没变时幂等,账本字节不变);见 §10「已知边界」。旧账本没有 F 签名时会先补扫一次且不误报变更。adoptExisting: true 是首次建账本的捷径:无上一版账本、清单可用时,逐条校验清单里的文件(相对路径在 sourceRoot 内、verified、sha256 一致),能对上的直接采信为证据而不重导出,数量回在 adopted |
- 与工具走同一条路径:每个方法都构造与对应工具相同的操作与参数、复用
runOperation, 所以模型面与服务面不会在默认值或错误形状上互相漂移。 - 失败语义与 §8 一致:操作级失败(TIA 拒绝、块不存在)返回
ok:false+ 结构化error; 传输级失败(找不到 exe、超时、协议不匹配)抛出。 - 不新增模型工具:新增的
readPlcChecksum/syncScan落在两个服务专用操作上 (PlcChecksum/SyncScan),模型面工具数不因此增加(当前 39 个);操作数为 40(v0.1 5 个 + v0.2 20 个 + F/版本取证 2 个 + 在线/下载/接管 6 个 + 硬件 5 个 + 块编辑器 1 个 + 项目库 1 个)。 这两个操作刻意不注册成工具:逐块比对指纹是版本管理工作流的一步,不应由模型手工编排。 - 它是可选的:消费方按名取(
ctx.get('engineeringAccess')),取不到就降级 —— 读上一次的指纹工件并明确报过期,而不是装作数据是新的。 - 为什么"翻页"在 V17 上不存在、为什么
closeProject这样定、source/布局为什么归本插件:docs/decisions.mdD20 / D21;契约镜像在packages/dsh-engineering-context/docs/ARCHITECTURE.md§5.3。
4.5.1 projectTextAccess:项目文本/语言的写缝
src/project-text-access.ts 暴露:exportTexts / importTexts / readLanguages /
setLanguages / archiveProject / saveProject / listBlocks。它同样复用
runOperation,与模型面的 project_texts / project_languages / save_project /
archive_project / list_plc_objects 走同一条路径。
- 不放进
engineeringAccess:那个缝的定位是读;importTexts不可回滚、setLanguages会改项目语言配置,必须让调用方显式处理权限与回滚。 listBlocks只为按programmingLanguage=F_*识别 F 块;组名是用户任意命名的,不能用于排除。- 模型面工具数不变:这些方法只是给工程上下文插件的工作流用的服务面,不新增工具。
4.6 斜线指令:/tia-…(/commands 行)
DSH 的斜线指令是绕过模型的直接执行面:命令行与结果都不进模型上下文,UI 只落一张可折叠的 结果卡(折叠时只显示正文第一行)。因此只有"人能在一行里说清、结果能一眼看完"的操作才做成命令; 需要 dry-run → 复核 → apply 的结构化写入(导入、删对象、写变量、改属性、保护块)仍然只走模型工具。
| 命令 | 语法 | 映射 | 默认行为 |
|---|---|---|---|
/tia-open | 无参数 | OpenProject | 打开本工作区的 TIA 项目,可见窗口;不升级旧工程 |
/tia-save | 无参数 | SaveProject | 就地保存 |
/tia-compile | 无参数 | CompilePlc | 编译当前 PLC,最多回 50 条消息 |
/tia-close | 无参数 | CloseProject | 保存、关闭工程并关掉 TIA Portal(save:true, close_portal:true) |
/tia-info | [sections…] | ProjectInfo | 默认 attributes comment software;history_limit=10、max_objects=50 |
/tia-find | <substring> [--blocks] [--types] [--tables] [--units] [--fp] | ListPlcObjects | 默认块/类型/变量表,max_items=50 |
/tia-status | 无参数 | —(控制器快照) | 从不启动控制器,只读状态 |
/tia-open不带路径:先读source/_dsh-engineering-context.json的project.savedAs, 没有索引就扫tia/<name>/<name>.ap17;只认工作区里的副本,绝不打开project.path指向的源工程。 找到多个就报错列出,不猜。/tia-close是一个动作:保存 → 关闭工程 → 关掉 TIA Portal,没有 flag、没有 dry run。 斜线指令本来就是图快,用户按下去之前就知道它做什么;close_portal:true也正是把实例释放掉、 让下一次/tia-open干净地重开的那一步(控制器会丢掉已随实例退出的TiaPortal句柄, 见OpennessHost.cs的PortalResponsive)。- 结果是给人看的文本:每条命令的第一行是摘要(如
Opened Sino_PEI — 1 PLC software, 1155 block(s)), 其余是多行详情;失败时沿用工具的Error code / Reason / Hint渲染。 - 命令不写模型历史:
/tia-open、/tia-save执行后模型并不知道状态变了;需要模型接着做时, 让它先调project_info/controller_status,或直接在对话里说明。 - 取消是协作式的:命令卡上的取消只停止等待,TIA 侧的 Openness 操作不保证被打断。
4.7 项目库工作流(project_library)
项目库有两棵独立的树,语义不同,工作流也不同:
| 树 | 有无版本 | 本插件能做什么 |
|---|---|---|
Types(类型) | 有(InWork / Committed,可设默认版本) | 枚举、导出某个版本的 XML、查依赖/被依赖/实例、设默认版本、删除;V17 Openness 没有 Import/CreateVersion/Release API,所以"发布新版本"只能在 TIA Portal 界面做 |
Master copies(主副本) | 无(名字就是身份) | 枚举、从工程对象创建、从编辑后的 XML 创建、复制、改名、删除、实例化回工程、导出内容 |
首次把已有工程的项目库纳入受控,用 action=export 一次性写 <workspace>/library/(每个类型版本
一个 XML + 每个主副本一个 XML + _manifest.json);之后再用 read/publish 做增量修改。
source/ 里已有的 blocks/types/tag tables 是 PLC 软件树,与项目库是两套对象,不需要因为
项目库能力而重导。
因此"编辑并发布新版本"的可执行闭环是:
project_library action=read kind=type_version把某个已发布版本导出成 XML(默认落<workspace>/library/types/<name>@<version>.xml);- 编辑 XML(块/UDT 的 Simatic ML;库版本包装层会在导入时自动剥掉);
project_library action=publish kind=type_version source=file allow_master_copy_fallback=true:把编辑后的内容发布成主副本,用name/version_label记录版本号(例如UDT_MotionPara_v2);- 需要回工程时
action=use operation=instantiate,或从工程对象直接发布主副本(source=project_object)。
真正的类型版本发布(新建版本 + Release)在 V17 只能走 TIA Portal UI;工具会返回
library_type_version_publish_unsupported,details.uiSteps 给出界面步骤,details.fallback 给出上面的主副本闭环。
完整参数、错误码与实测限制见 docs/PROJECT-LIBRARY.md。
5. 安全设计
| 措施 | 实现 |
|---|---|
| 操作白名单 | 控制器只接受 controller/Protocol.cs 的 OperationCatalog 里的 40 个操作名(v0.1 的 5 个 + v0.2 的 20 个 + F/版本取证 2 个 + 在线/下载/接管 6 个 + 硬件 5 个 + 块编辑器 1 个 + 项目库 1 个);其它名字返回 unsupported_operation。插件侧 src/protocol.ts 的 OPERATIONS 是同一份列表(双重校验,互不信任),npm run matrix:check 逐条比对两者 |
| 禁止任意代码 | 控制器不接受任何 C#/脚本片段,所有参数都是数据(路径、块名、枚举);没有 eval / Invoke / Create 反射入口 |
| 事务与回滚 | 写入使用 TiaPortal.ExclusiveAccess() + ExclusiveAccess.Transaction(project, "...");只有全部文件成功后才调用 CommitOnDispose(),否则 dispose 即回滚,项目保持不变 |
| 写后验证 | 见 4.3 |
| dry-run | 见 4.2 |
| 无密钥 | 插件不读也不写任何 API Key;配置里只有路径与超时 |
| 资源清理 | 子进程通过 ctx.effect() 的 disposer 停止(异步且被框架 await);控制器退出/卸载时关闭项目并释放它自己启动的 TIA Portal 实例 |
| 结构化错误 | 控制器的任何异常都被转换为 {code, message, details};插件层的传输失败(找不到 exe、握手超时、超时终止)抛 ToolFailure,消息以错误码开头 |
注意:控制器子进程被强杀时(超时/取消),Openness 会话会丢失;由控制器启动的 TIA Portal 进程可能仍然驻留(它是一个独立进程,插件绝不会去杀它)。请用
close_project(close_portal: true)正常收尾。这一点在 README、工具描述和docs/PROTOCOL.md中都有说明。
5.1 第三方依赖与合规
构建期与运行期都用 Siemens 官方的 NuGet 包(见 §6.1)。 要点:
Siemens.Engineering.dll从不被本仓库分发(引用包CopyLocal=false),它始终来自用户自己的 TIA Portal 安装;controller/bin/里会随插件分发 Siemens 解析器及其 5 个依赖(约 889 KB,未做任何修改);- 完整清单、版本规则、许可证原文要点、以及"想要严格零 Siemens 二进制的分发包该怎么做",
都写在
THIRD_PARTY_NOTICES.md。
许可证正文(
LICENSE_NuGet.org.md,随每个包分发)是 Siemens 自定的 "Royalty-free Software ... for sharing platforms" 条款 +requireLicenseAcceptance=true; 第 2 条把 MIT 授予"包内包含或生成的源代码"。因此"引用并随应用分发这些公开 NuGet 库" 属于常规消费,而"你是否接受把这些 DLL 打进公开发布物"是一个需要你(或 Siemens SIOS)确认的判断——THIRD_PARTY_NOTICES.md里给了两种姿态的具体做法。
6. V17 API 要点(本仓库实测结论)
以下均以本机 Siemens.Engineering.dll(文件版本 1700.7.501.6,程序集版本 17.0.0.0)
编译验证,不是猜测:
IEngineeringObject成员(GetAttribute/GetAttributeInfos)在 V17 对所有实现类型隐式可见, 无需强制转换;PlcBlock.Export(FileInfo, ExportOptions)、PlcBlockComposition.Import(FileInfo, ImportOptions[, SWImportOptions]);PlcExternalSourceComposition.CreateFromFile(string name, string path)(注意先名字后路径)、PlcExternalSource.GenerateBlocksFromSource(GenerateBlockOption);- 事务:
TiaPortal.ExclusiveAccess()→ExclusiveAccess.Transaction(project, "描述")→Transaction.CommitOnDispose(); - 编译:
CompileProvider是 internal,公开的是ICompilable接口 (plcSoftware.GetService<ICompilable>().Compile())。这一点用编译器与反射共同确认过; PlcSoftware.BlockGroup(PlcBlockSystemGroup,继承PlcBlockGroup)提供Blocks/Groups/SystemBlockGroups;块元数据可直接读强类型属性(Name/Number/ProgrammingLanguage/ModifiedDate…)。
6.1 程序集解析:用 Siemens 官方 NuGet,而不是自研
控制器的 Openness 引用与运行时解析都由 Siemens 官方 NuGet 包提供(详见
THIRD_PARTY_NOTICES.md):
| 阶段 | 包 | 作用 |
|---|---|---|
| 构建 | Siemens.Collaboration.Net.TiaPortal.Packages.Openness 17.0.1685432625 | 纯 MSBuild 包:按 注册表 → TiaPortalLocation → 默认路径 的顺序找到 PublicAPI\V17 下的程序集,并以 CopyLocal=false 全部引用(Siemens.Engineering.dll / .Hmi.dll 因此永不进入产物)。包版本与 TIA 版本一一对应(V17→17.0.x,V21→21.0.x) |
| 运行 | Siemens.Collaboration.Net.TiaPortal.Openness.Resolver 1.1.1725480302 | 注册 Siemens 自己的 AssemblyResolve 处理器;检查注册表、正在运行的 TIA 进程与 TiaPortalLocation,在找到的多个 Siemens.Engineering 中挑选与编译版本匹配的那个。V2 只兼容 TIA V21+,所以 V17 锁 1.1 |
控制器在 OpennessBootstrap.cs 里做三件官方库不管的事:
- 惰性初始化:官方解析器在第一个操作前才初始化(
Initialize(tiaMajorVersion: 17)), 而不是进程启动时。这样没有可用 Openness 的机器仍能启动控制器、打印 ready 帧并给出结构化原因;--self-test也能断言"启动时未加载Siemens.Engineering"(20 项里的openness_not_loaded_by_startup)。 - 诊断:ready 帧里的
openness对象(resolvedFrom=registry/TiaPortalLocation/configured、assemblyPath、fileVersion/assemblyVersion、resolver/resolverVersion)由控制器自己读 注册表产出——官方库不提供等价信息,而它是controller_status与排障的主要依据。 - 兜底:
--openness-dir会被翻译成TiaPortalLocation交给官方解析器;同时注册控制器自带的 目录探测作为最后手段(handlers 后注册者先执行,所以官方解析器始终优先,兜底只在"谁都解析不出来" 时生效)。官方初始化失败也不再致命:记录诊断、降级到兜底探测、下个操作重试。
注意
Initialize有个坑:位置参数Int32的重载是 TIA 进程 id(用于附加到已运行的 TIA), 不是版本号;版本必须用命名参数tiaMajorVersion:。传错会得到Process with an Id of 17 is not running。
7. 测试
npm run check # 编译 TS + 运行全部测试
npm test # 只跑测试
npm run test:controller # 只跑 C# 控制器自检
测试套件(test/*.test.mjs,node --test):
| 文件 | 覆盖 |
|---|---|
01-load.test.mjs | 加载与拆分契约:两行的模块级 name/inject/apply(宿主行 inject: [],工具行 ['tools', 'tiaOpennessRuntime']);工具行按注册顺序注册相同的 39 个工具、宿主行一个工具都不注册、缺少宿主行时工具行报错;参数与输出 schema 用真实 @deepseek-ai/dsh-tools 编译器编译;校验器拒绝缺参/错类型/越界枚举;工具描述包含 dry-run 策略与错误码;工具返回值通过 output schema 校验;控制器缺失时宿主行仍能加载并给出结构化原因 |
02-lifecycle.test.mjs | 生命周期测试:用真实 exe 启动控制器,断言操作系统可见该进程;ctx.effect 的 disposer 卸载后断言进程已消失;卸载幂等;配置了不存在的路径时调用失败为 controller_not_found。注意:触发卸载的是测试里忠实模拟 ctx.effect 语义的 disposer,不是真实 DSH loader 的 HMR 路径(该环待人工验证) |
03-controller-protocol.test.mjs | 协议测试:握手、白名单拒绝、参数校验、project_not_open、ASCII 转义、进度帧、请求串行化、队列上限;用 stub 控制器覆盖卡死超时→终止→重启、请求中途退出、协议版本不匹配、stdout 噪声(这一组还捕获并回归了一个真实的 bug:被替换的旧子进程的迟到 exit 事件会清掉新子进程引用,导致进程泄漏) |
04-tools.test.mjs | 工具语义:每个工具发送的参数与默认值、dry-run 只留给预览带信息量的工具(含 project_library 的写子面,决策 D22)、只发送白名单操作、controller_status 不触碰控制器、渲染文本包含错误码/提示/诊断 |
05-controller-cli.test.mjs | C# 控制器:--self-test 20 项检查全绿;Openness 探测与用户组;--version/--help;命令行输出重定向为结构化帧;--param 重复值成数组 |
06-skills.test.mjs | 知识库(替身注册表):宿主行 ctx.inject(['skills'], …) 注册;没有 skills 服务的 profile 仍加载控制器与全部工具;目录只多一条且 description ≤ 500;get() 正文无 frontmatter、引用的每个上游文件都存在、正文 < 8192;vendored 树与 UPSTREAM.json 一致;每个工具描述都指向该 skill |
07-skills-registry.test.mjs | 知识库(真实注册表):把 @deepseek-ai/dsh-skill 的真实 SkillRegistry 挂到裸 cordis context 上(不需要工具注册表,因为宿主行已不含工具),验证 candidate 被真实校验接受、重名注册被拒、get() 能加载、renderSkillContent 带上 base directory、卸载宿主行后目录项消失 |
08-access-service.test.mjs | 服务缝:engineeringAccess 每个方法发送与对应工具相同的操作与参数、族信封摊平、截断如实上报、closeProject 必须显式给 dryRun、操作级失败回数据而传输级失败抛出;宿主行发布内部 tiaOpennessRuntime 缝(恰好三个成员)且卸载后消失 |
09-two-rows.test.mjs | 两行接线的真实服务图:把两行当兄弟插件挂在裸 cordis Context 上(只有记录用的 tools 服务),断言工具行的 inject 由宿主行满足、跨行读到 tiaOpennessRuntime 并注册同名同序的 39 个工具;宿主行自己一个工具都不注册,卸载后缝消失 |
C# 控制器自检(无需 TIA Portal,20 项):
controller\bin\TiaOpennessV17Min.Controller.exe --self-test
7.1 构建 C# 控制器需要什么(含国内网络实测)
npm run build:controller 会做一次 NuGet 还原。本机实测(中国移动网络,未挂 VPN):
| 项 | 实测 |
|---|---|
api.nuget.org v3 索引 | HTTP 200,约 1.0 s |
globalcdn.nuget.org 下载 | 2.4 MB / 约 2.0 s(≈1.2 MB/s) |
冷缓存 dotnet restore(2 个 Siemens 包 + 6 个传递依赖,--no-cache + 清空 http-cache) | 13.3 s |
随后的 dotnet build | 2.1 s(已还原,离线可重复构建) |
| 华为云 NuGet 镜像 | 收录这两个包(索引 259–692 ms,35 / 8 个版本),可作为加速或兜底 |
结论:不挂 VPN 就能构建成功;首次 13 秒,之后走本地 NuGet 缓存(~/.nuget/packages)无需联网。
若所在网络访问 nuget.org 不稳定,切换镜像即可:
dotnet nuget add source https://mirrors.huaweicloud.com/repository/nuget/v3/index.json -n huawei
dotnet restore controller\TiaOpennessV17Min.Controller.csproj --source huawei
注意:控制器的运行时不联网、不还原——发布物里已包含所需程序集(见
THIRD_PARTY_NOTICES.md),只有"重新构建控制器"这一步需要 NuGet。
真实 TIA 项目的功能测试(导出 → 修改 → 导入 → 编译)见
docs/FUNCTIONAL-TEST.md。
测试用的运行时包链接
插件像任何已发布插件一样 import '@deepseek-ai/dsh-tools' 等,运行时由 profile 的
runtime resolution 解析。裸 checkout 里跑测试需要一次性链接:
pnpm run link:runtime # 从已安装 app 的 app.asar 抽取运行时并链到 node_modules
pnpm run link:runtime -- --force # 无视缓存,按当前宿主版本重抽
抽取来源是已安装 app 自己的 resources/app.asar,也就是宿主正在用的那份运行时,
按 dependencies + peerDependencies 求闭包后解包到 <DSH_HOME>/plugin-runtime,
并记下宿主版本;宿主升级后下次运行会自动重抽。找不到安装位置时可用环境变量
DSH_APP_ASAR 指定 asar,或用 DSH_HOME 指向另一个 harness home。
(这些链接只用于本地开发与测试,不会被打包,也不影响已安装插件的行为。)
8. 错误码
| 错误码 | 含义 / 处理 |
|---|---|
openness_unavailable | 找不到 Siemens.Engineering.dll:确认 TIA Portal V17 已安装,或用 opennessDir 指定路径 |
openness_load_failed | DLL 存在但无法使用(位数不符/依赖缺失):确认 x64 与安装完整性 |
project_not_found | 项目文件不存在 |
project_not_open | 需要先 open_project |
project_already_open | 已打开一个项目:先 close_project |
project_open_failed | 打开失败(多为旧版本项目:需要 allow_upgrade) |
plc_software_not_found / plc_software_ambiguous | 项目中找不到/找到多个 PLC 软件:传 device_name / software_name |
block_not_found | 指定块不存在,details.available 给出项目里的块清单 |
invalid_params / invalid_file | 参数或输入文件不合法(invalid_file 表示 XML/外部源格式问题) |
export_failed / import_failed / compile_failed | Openness 调用本身失败,details.hint 给出常见原因 |
verification_failed | 写入后读回验证未通过(data 仍包含已发生的写入与验证报告) |
transaction_failed | 无法获得独占访问事务(可能有另一个 Openness 客户端在改项目) |
unsupported_operation / unsupported_frame | 越出白名单的请求被拒绝;details.allowed 列出全部允许的操作名 |
library_type_not_found / library_type_ambiguous / library_version_not_found | 项目库类型/版本定位失败;details.available / details.candidates 给出候选(同名类型请用 guid 或更窄的 folder) |
library_version_in_work | 该版本是 InWork,Openness 拒绝导出;改用 version=committed 或已发布版本号 |
library_master_copy_not_found / library_master_copy_ambiguous / library_master_copy_exists | 主副本定位失败/同名/目标名已存在;mode=replace 或换 name/version_label |
library_master_copy_inconsistent | 主副本内容在 TIA 里不一致(例如引用的 UDT 缺失),Openness 拒绝导出/实例化;先在 TIA 里修好 |
library_master_copy_export_unsupported / library_master_copy_instantiate_unsupported | 该主副本是 HMI/硬件等本插件不路由的对象;不会猜目标去创建 |
library_type_version_publish_unsupported | V17 没有类型版本的 Import/CreateVersion/Release API;details.uiSteps 给界面步骤,details.fallback 给主副本闭环 |
confirmation_required | action=organize operation=delete 需要 confirm=true 且 dry_run=false |
library_managed_block | import_blocks 拒绝覆盖项目库类型版本的实例:直接 XML 导入会绕过 TIA 的 check-in/release,实例会脱离库并变成 inconsistent。走库感知流程,或显式 allow_library_managed_import=true |
delete_failed / object_not_found / object_already_exists | v0.2:删除对象失败 / 目标不存在(details.missing、details.available)/ 已存在 |
project_create_failed / project_save_failed | v0.2:新建工程失败(目录非空、名称含非法字符等)/ 保存或另存失败 |
project_not_saved | v0.2:archive_project 前工程有未保存改动(手册要求先 Save) |
archive_failed / archive_not_found / retrieve_failed | v0.2:归档写入失败 / 归档文件不存在 / 取回失败 |
language_not_found / language_change_failed | v0.2:工程不支持该语言(details.available 给出支持列表)/ 语言设置失败 |
project_text_export_failed / project_text_import_failed / project_update_failed | v0.2:工程文本 xlsx 导出/导入失败 / 工程属性或注释写入失败 |
setting_not_found / setting_change_failed | v0.2:TIA Portal 设置项不存在(列出可用文件夹与设置)/ 写入失败 |
group_not_found / group_not_empty / group_create_failed | v0.2:用户组不存在 / 非空不能删 / 建组失败 |
tag_table_not_found / tag_not_found / tag_create_failed / tag_update_failed / constant_create_failed / constant_update_failed | v0.2:标签表或变量/常量不存在与写失败 |
attribute_not_writeable / attribute_write_failed | v0.2:属性没有写权限(GetAttributeInfos 无 Write)/ 写入失败 |
protection_unavailable / protect_failed / unprotect_failed | v0.2:块不可 know-how 保护(provider 为 null)/ 加保护失败 / 解保护失败 |
generate_source_failed / file_exists | v0.2:生成源文件失败 / 目标文件已存在且未给 overwrite |
watch_table_not_found / force_table_not_found / table_create_failed / table_delete_failed | v0.2:监视表或力表不存在、建删失败;力表在 V17 既不能建也不能删(限制 R15) |
unit_provider_unavailable / unit_not_found / unit_exists / unit_create_failed / unit_delete_failed / relation_create_failed | v0.2:软件单元——该 PLC 不支持 / 单元不存在或已存在 / 建删失败 / 关系建立失败 |
global_settings_unavailable / safety_setting_failed / signature_read_failed | v0.2:没有 Siemens.Engineering.Safety.GlobalSettings 服务(未装 STEP 7 Safety)/ 写 F 相关设置失败 / 读 F 签名失败(非 F 块不报错,回报 isFBlock:false) |
controller_not_found | 插件找不到控制器 exe:npm run build:controller 或配置 controllerPath |
controller_timeout / controller_cancelled | 超过 requestTimeoutMs 或被取消:控制器已被终止,下次调用会自动重启(TIA Portal 会话丢失) |
controller_exited / controller_spawn_failed / controller_handshake_timeout | 控制器启动/运行异常,details.stderr 带控制器自身输出 |
controller_busy | 排队超过 maxQueue |
controller_protocol_mismatch | exe 与插件版本不一致:用同一份仓库重新构建 |
cax_unavailable / cax_export_failed | v0.3:该工程拿不到 CaxProvider 服务 / CAx 导出抛异常或根本没产出文件(details.logSummary、details.logProblems 带 TIA 日志结论与 ERROR 行)。注意"有对象被跳过"不算失败:那是 ok:true + data.allObjectsExported:false |
exclusive_access_failed | v0.3:拿不到独占访问(另一个 Openness 客户端正占用 TIA Portal) |
output_exists | v0.3:目标 AML 已存在且 overwrite=false |
scope_unavailable | v0.3:会话没有工作目录,export_hardware_config 无法推导默认落盘位置(改传绝对 output_dir) |
hardware_aml_not_found / invalid_aml | v0.3:找不到 AML(先跑 export_hardware_config)/ 文件不是 CAEX 文档(根元素不是 CAEXFile,或没有 InstanceHierarchy) |
device_not_found(硬件读取) | v0.3:device 参数给的设备名不在 AML 里,details.available 列出全部设备名 |
item_not_found / item_ambiguous / attribute_not_found | v0.3:hardware_parameters 的设备项路径不存在 / 有多个同名项(details.candidates)/ 该对象不发布这个属性(details.available 给全部属性名) |
排障第一步永远是:
{ "include_controller_output": true } // controller_status:进程状态、exe 路径、Openness 探测、用户组、最后错误
9. 仓库结构
src/
index.ts 宿主行入口:name / inject[] / Config / apply,ctx.effect 拥有子进程
tools-entry.ts 工具行入口(exports["./tools"]):读 tiaOpennessRuntime,注册 39 个工具
commands-entry.ts 命令行入口(exports["./commands"]):读 tiaOpennessRuntime,注册 7 个 /tia-… 斜线指令
runtime-service.ts 宿主行与另两行之间的内部缝 tiaOpennessRuntime(恰好 request/status/verbose)
config.ts Schemastery 配置 schema + 归一化(所有字段有默认值)
controller.ts C# 控制器的生命周期、NDJSON 帧、串行化、超时与终止
protocol.ts 线路类型 + 容错帧解析 + 统一结果信封
skills.ts 知识库:把 skills/ 注册成一个 bundled skill(ctx.inject(['skills'], …))
tools.ts 39 个 defineTool 定义(模型可见描述)与渲染;工具行/命令行共用的唯一实现
commands.ts 7 个斜线指令:单行语法解析、首行摘要、工作区工程定位
errors.ts ToolFailure(传输层错误)
dsh-runtime.d.ts 本插件用到的 DSH 运行时类型(离线可构建)
skills/ 随包出货的 Openness 知识库:31 个上游 SKILL.md(逐字,MIT)+ 路由 skill(见 §4.4)
tia-openness/SKILL.md 本仓库维护:症状→文件路由表(< 8192 字符)
UPSTREAM.json 生成物:上游 commit、逐文件 sha256、许可证、被排除项
LICENSE.siemens.txt 上游 MIT 许可证全文(随副本出货的合规要求)
controller/
Program.cs 入口:参数解析、stdio 服务循环、一次性 CLI、self-test
Protocol.cs 帧常量、操作白名单、结构化异常、诊断与变更日志
Json.cs 有序 JSON 写出器 + 参数读取器
OpennessBootstrap.cs 用 Siemens 官方 NuGet 解析器加载 Openness(惰性,首个操作用到才初始化)
OpennessHost.cs TiaPortal/项目会话、事务、块遍历、元数据读取
Operations.cs 白名单操作:块/类型/标签表导出导入、编译、开关工程(dry-run、事务、写后验证)
OperationsProject.cs v0.2 工程与工程数据(创建/保存/归档/取回/信息/语言/文本/设置)
OperationsPlc.cs v0.2 PLC 设备数据(枚举/建删/变量/属性/保护/生成源/监视表/软件单元)
OperationsSafety.cs v0.2 F 相关(GlobalSettings、SafetyAdministration、F 签名)
OperationsEditor.cs 块编辑器:ShowBlocksInEditor(IShowable.ShowInEditor,批量打开,需带界面的 TIA)
OperationsOnline.cs 在线目标发现(PC 接口/网段/设备 IP)与控制器持有的在线会话
OperationsLibrary.cs 项目库:ProjectLibrary 的 browse/read/write/publish/organize/use
OpennessHost.cs 会话:TIA Portal 实例、工程、独占访问事务、块遍历
OpennessHost.Project.cs / .Plc.cs / .Safety.cs / .Online.cs / .Library.cs 上述各块的宿主侧实现
SimaticMl.cs Simatic ML XML 头解析、库版本包装层剥壳与 SCL/STL 外部源扫描
SelfTest.cs 20 项无 TIA 自检
test/ node:test 测试套件
test-profile/ 试跑材料:三层验证指南 + 两个脚本 + --patch 叠加层(不改默认 profile)
docs/PROTOCOL.md 线路协议与错误码(权威描述)
docs/EXTENDED-SURFACE.md v0.2 新增 20 个操作的参数与返回契约(冻结)
docs/PROJECT-LIBRARY.md 项目库的能力边界、工作流与真实项目实测
docs/VERIFICATION-PLAN.md v0.2 新增能力的真实项目验证清单(待执行)
docs/KNOWLEDGE-BASE.md 知识库在哪、为什么不放 docs/、怎么更新(见 §4.4)
docs/FUNCTIONAL-TEST.md 真实项目功能测试步骤
docs/REAL-PLC-DOWNLOAD-ASSESSMENT.md 真实 PLC 下载能力评估(现状、缺口、建议)
docs/verification.md section 8 验证清单逐条核对 + 待人工验证步骤
docs/decisions.md 技术取舍记录(被否方案与理由)
docs/coverage-matrix.html 折叠式能力覆盖矩阵(生成物,随代码更新;可按能力主题筛选;见 scripts/coverage/)
scripts/link-dsh-runtime.mjs 本地开发/测试用:把运行时包链到 node_modules
scripts/dsh-runtime-cache.mjs 从已安装 app 的 app.asar 抽取运行时闭包到 <DSH_HOME>/plugin-runtime
scripts/asar-read.mjs 最小 asar 读取器(供上一条使用)
scripts/coverage/ 覆盖矩阵的数据、快照抽取与生成/校验脚本
scripts/knowledge/build-skills.mjs 知识库同步(联网重取上游)与离线校验(--check)
.tools/asar.cjs 开发工具:无依赖读取 Electron app.asar(不属于插件运行时)
10. 已知边界
- 真实环境验证已完成(§0.1、
docs/REAL-RUN.md): 真实 DSH 宿主加载/退出、真实 237 块项目的导出→改→导入→编译。 只剩两项需要人/其他环境补充:运行中实例里的 HMR disposer 动作(UI 里禁用/启用插件), 以及 V18+ 的 Openness 应用白名单策略(本机 V17 未拦截)。 - 真实项目里的块不一定都能导出:ProDiag 语言块与 Safety(F-)块被 TIA 直接拒绝,
控制器逐块报告(
data.failures[])并继续;导入必须指定块原来所在的组(target_group), 且"导入后重新导出"要放在编译之后。三条约束见docs/FUNCTIONAL-TEST.md§8.5。 - F-CPU(安全型)工程的仿真/下载:项目数据不能下到标准 CPU 的 PLCSIM Advanced 实例
(PLCSIM Advanced V7 手册 §7.4 "Loading project data of an F-CPU to a standard CPU is not
possible";TIA 报"虚拟 PLC 型号与项目 PLC 型号不符")。实例必须用
unspecified或同型号 F; 且 V17 Openness 对 F 激活 PLC 一律download_unavailable(限制 R16),只能从 TIA Portal UI 下载。模型在用户要求仿真安全型 PLC 时必须先说明"套件无法自动完成下载/仿真",不要报运行缺失。 详见docs/HANDOFF-PLCSIM-DOWNLOAD.md§10.4 与本包skills/tia-openness/SKILL.md。 - 块、PLC 类型与标签表仍是核心,但已不止于此:
export_blocks/import_blocks用categories选择blocks(默认)/types(PLC 数据类型 UDT)/tag_tables,三族对象互不冲突; v0.2 又补上工程生命周期与工程数据(create_project/save_project/archive_project/project_info/project_languages/project_texts/update_project/portal_settings)、PLC 对象增删改 (list_plc_objects/create_plc_objects/delete_plc_objects/write_tags/set_block_attributes/protect_blocks/generate_source/watch_and_force_tables/software_units)与 F 相关 (safety_status/set_safety_settings/safety_signatures),v0.3 再加上硬件组态的读方向 (export_hardware_config:工程级 CAx/AML 导出,见下一条)。仍未实现:硬件组态的网络与设备对象模型读取 (子网/节点/IO 系统/端口互联/地址/通道)、硬件组态的导入与设备级 AML 导出、AML 解析、 在线会话与下载已接线(adopt_open_project/online_targets/online_connect/online_status/online_disconnect/download;V20+PLCSIM 已验证 adopt 后下载,V17 未实测);上传/在线比较、全局库(GlobalLibrary)与全局库归档、多用户、HMI、OPC UA、工程图形删除、只读/UMAC 打开、 力表的创建与删除(V17 无相应 API,见限制 R15)。完整的逐条覆盖情况见docs/coverage-matrix.html(随代码自动重新生成)。 页面顶部「能力主题」可按扩展主线一键筛选现有子集(如「在线与下载」,13 条能力;R/H 冗余站与 PC System 已按 2026-10-24 口径显式排除并记在excluded里), 主题定义在scripts/coverage/matrix-data.mjs的SCOPES,加一条即多一个筛选入口。 PLC 类型与标签表可以被导入,但块的读回验证覆盖不到它们(会给出 warning)。 - AML 不是完整的硬件清单:
export_hardware_config走手册 "Export of CAx data" 的CaxProvider.Export(project, aml, log),而该条目同时列出 CAx 无法导出/导入的对象——驱动、 除按键面板与按键面板类以外的 HMI 设备、多 CPU 站、端口到端口连接、扩展机架之间与到扩展机架的连接、 模拟量通道的输出模式与量程、压缩地址(另有一批不支持的 MLFB)。这些都不在文件里,而不是"空着"。 工具本身只产出文件、不解析 AML;设备级导出(Export(device, …))未暴露。 该能力的逐条筛选与后续路线见docs/HARDWARE-CONFIG-SCOPE.md。 - v0.2 的 20 个操作尚未在真实项目上验证:已实现、编译、单测通过,但真实 TIA Portal 行为
(尤其是
archive_project的取回、project_texts的 xlsx 往返、software_units需要支持 软件单元的 CPU、safety_*需要 STEP 7 Safety 与 F-CPU)留待逐条执行docs/VERIFICATION-PLAN.md。在跑完之前不要把这些操作当成 "已在 V17 上实测"向他人转述。 - 导入的目标组固定为根块组:TIA 的导入不保留导出时的用户组层级,导出仍会按组写目录。
- 项目库:类型版本只能读,不能经 Openness 发布:V17 的
LibraryTypeVersion只有Export, 没有 Import/CreateVersion/Release,State(InWork/Committed)是只读的。因此project_library对类型版本提供导出、依赖/实例查询、设默认版本与删除;"编辑后发布新版本"的可执行闭环是 导出类型版本 XML → 编辑 → 作为主副本(Master copy)发布,用name/version_label记录版本号。 真正的类型版本发布仍须在 TIA Portal UI 里完成,工具以library_type_version_publish_unsupported返回details.uiSteps。主副本是无版本的,这一点不要向调用方含糊。实测(SWT2,280 类型 / 424 版本 / 8 主副本)见docs/PROJECT-LIBRARY.md。 - 项目库的 HMI / 硬件主副本不支持:
project_library的主副本导出/实例化只路由 PLC 块、PLC 类型、 PLC 标签表;HMI 标签表、画面、面板与硬件设备主副本会返回library_master_copy_export_unsupported或library_master_copy_instantiate_unsupported,不会猜一个目标去创建。 - 一次一个宿主进程一个 TIA Portal 会话:不同 DSH 会话共用同一个控制器并排队。
- 超时即丢失会话:Openness 不可取消,超时的唯一可靠处理是终止控制器。
- F 块改动不会移动 PLC checksum(同步盲区,
force_scan绕过):PlcChecksumProvider.Software覆盖编译后的标准程序;只改安全程序时它保持不变,SyncScan的 checksum 快速路径因此会 不枚举、不问SafetySignatureProvider就回答unchanged。表现是版本管理工作流里"只改了 F 块 →project_sync说没有变化 →project_commit提交不了"。解法是syncScan({ forceScan: true })(工具面project_sync({ force: true })):强制枚举并按 F 签名比对,工程真没变时幂等 (不写 XML、账本字节不变,提交仍为空)。V17 公开 API 里没有"整个安全程序一个签名",逐块SafetySignatureProvider是唯一权威口径(反射实证:SafetySignatureType只有BlockOfflineSignature一个成员)。data.scanSkipped明确区分"checksum 相同所以跳过"与 "真的比过"。
11. 参考与致谢
设计参考(未复制任何代码):
- Siemens TIA Portal Openness V17 系统手册(API 行为与事务/编译用法的最终依据)
- siemens/tia-portal-ai-extensions —— 技能划分与诊断思路
- huahaizo/tia-portal-openness-ai —— "注册解析器 → 加载 DLL → 业务逻辑" 的控制器分层思路
明确未使用:TiaCommander 的任何代码;Siemens Skills 仓库中的 C# 代码。 唯一被复制过来的上游内容是文档:Openness skill 集(§4.4)按 MIT 逐字 vendor, 附上游许可证全文与逐文件 sha256,代码一行未取。
许可证:MIT(见 LICENSE)。
Badge
Listed here? Link back with this badge — paste the snippet into your repository README.
[](https://dsh-plugin.com/plugins/voltarenyah/dsh-automation-suite/packages/dsh-tia-openness-v17-min)